Signal Processing Asked on October 24, 2021
if we take a sinus with Fd=100KHz with fs=1000KHz sampling rate We do an FFT with 256 members we get energy leakage.
Why choosing Fd=113.28Khz solves this problem?
Thanks
See my answer here on how to work with the units in question:
DFT exercise in the book Understanding digital signal processing 3 Ed
Then apply the fact that leakage does not occur when the DFT frame covers a whole number of cycles of your tone signal.
$$ Fs = 1000000 frac{Samples}{Second} $$
$$ Fd = 113280 frac{Cycles}{Second} $$
$$ N = 256 frac{Samples}{Frame} $$
$$ frac{Fd}{Fs} cdot N = frac{frac{Cycles}{Second}}{frac{Samples}{Second}} cdot frac{Samples}{Frame} = frac{Cycles}{Frame} $$
$$ frac{113280}{1000000} cdot 256 = 28.99968 $$
Which is pretty darn close to a whole number.
Answered by Cedron Dawg on October 24, 2021