SharePoint Asked by SavantProdigy on October 25, 2021
Event Type: Error
Event Source: Office SharePoint Server
Event Category: Publishing Cache
Event ID: 5785
Date: 7/30/2013
Time: 4:38:10 PM
User: N/A
Computer: MSMOSSWEB1
Description:
Unable to connect publishing custom string handler for output caching. IIS Instance Id is ‘1458748636’, Url is ‘ site name and _layouts/images/filter.gif’.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
There are many more with different errors but same event ID
I am on MOSS June 2011CU,does anybody know anything about this , this error is right from the morning till evening and keeps coming every 2-5 min i am afraid this will fill up the logs and the machine might run low on space
Please advice.Thanks in advance
Looks like the solution is to modify the web.config. I haven't tested, ymmv, be sure to make a copy of your web.config before starting, etc.
http://vettekerry.wordpress.com/2008/05/19/fix-the-annoying-event-id-5785/
The solution is to modify the web.config of the application. Remove the PublishingHttpModule module that was added by the root web.config:
<httpModules> <remove name=”PublishingHttpModule” /> </httpModules>
Answered by Eric Alexander on October 25, 2021