TransWikia.com

Where to connect C Wire to1990 Weil Mclain Steam Boiler

Home Improvement Asked by Jeff Lombardi on September 2, 2021

I am attempting to run a new 18/5 line in order to hook up an Ecobee 4 to my Weil Mclain boiler, as my current thermostat only has a R & W wire. I am having trouble figuring out where exactly to hook up the new C wire. Any insight would be helpful.

(https://i.stack.imgur.com/taTHr.jpg)enter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description hereenter image description here

One Answer

Looks like it should be terminal 2 based on the left hand wiring diagram. Verify it using a multimeter (should have 24v between 1 and 2, and 0 between 2 and chassis ground)

Answered by gbronner on September 2, 2021