TransWikia.com

Use Honeywell VisionPro without EIM?

Home Improvement Asked on March 20, 2021

I just acquired a Honeywell VisionPro TH9421C1004 thermostat but I didn’t get the Equipment Interface Module (EIM) with it. Can I still wire this directly from my furnace? It only has 3 wire connections: Data, R, and C.

One Answer

No, you can't

Unfortunately, the Honeywell thermostats that use an EIM rely on it to translate either RedLink (for wireless versions) or a proprietary protocol (for the wired ones) to the 24VAC signals that a furnace understands. So, since Honeywell discontinued the wired versions in favor of their RedLink counterparts, you'll need to hunt down a secondhand EIM for your thermostat.

Answered by ThreePhaseEel on March 20, 2021