Smell from recently capped chimney

Home Improvement Asked by aucuparia on December 25, 2020

We had our chimney capped a couple of months ago (the next-door semi were having theirs done, so we said “yes” to their contractor doing ours at the same time). The contractor has removed the chimney pots and all that is visible from the ground is sloped mortar on top of the stack. It’s possible there is no ventilation at the top – there’s certainly nothing protuding very high above the top of the stack and no air bricks are visible.

The fireplace is still open (just covered with a sheet of plywood with a hole in it) in the room below.

A couple of days ago a very strong dusty/sooty/musty smell started in the room with the fireplace. There is also a noticeable draught coming from the fireplace. Neither of these were present at any time before the chimney was capped. This has coincided with a period of strong winds (though I can’t see any damage to the chimney stack).

Is it possible the smell is due to condensation from the now inadequately ventilated chimney, and the draught is just due to air pressure changes in the room (annoyingly it’s worse with the windows open) sucking air in and out of the closed chimney? Or is it more likely the stack has been damaged nd leaking?

And am I right in thinking the correct action is to get the chimney properly ventilated at the top? Is it going to need cleaning as well?

One Answer

You are likely correct with your analysis.

All the properly capped chimneys I have seen have an air vent top and bottom to allow slower air movement compared to the original chimney.

When people have "hidden" the fireplace but not capped the chimney, they sometimes just put a mesh over the top end of the chimney to prevent birds getting in and an air grate as part of the fireplace cover.

Allowing the air to move is a crucial part of the chimney "removal" process. Either improve the ventilation or consider removing the chimney totally or at least taking the lower part away and leaving the part in the attic - make sure it has sufficient support.

Answered by Solar Mike on December 25, 2020