Home Improvement Asked by Arvisionz on September 25, 2020
I just changed the filter for my National Comfort model CPG41238-U23 AC unit and now the unit is not turning on. Initially it was turning on but constantly short cycling every 30 seconds. Now the unit is only blowing air via the fan. Does anyone know why this is happening? It is a relatively new unit and it was working perfectly fine until I replaced the filter. Thanks.
The brand and model of the HVAC unit is National Comfort Brands, Model CPG41238-U23
So currently the unit says its cooling according to my thermostat but it clearly is not as the temperature on the thermostat has been at 78 all day and I have the temperature set to 70. There is no cold air coming out of the vents, just the fan seems to be on. I checked to see if the heating works and it seems to be working just fine. The cooling is just not working. I looked for the switch that dandavis mentioned and there is a switch that seems to be triggered when the slotted door to the filter is opened/closed. There is no actual switch or anything that is directly touching the filter, only the slotted door. I turned the cooling off via the thermostat and then I turned the unit off using the lightswitch located near the unit. I checked the circuit breaker and nothing was tripped. I turned off the unit via the circuit breaker, waited 1 minute then flipped the circuit back on, then turned the unit on via the lightswitch, waited for my thermostat to reboot then turned on cooling. Still no luck. Here are some attached pictures of the units filter area including the switch I Found, the thermostat reading, as well as more information about the model. Thanks again for the help.
Also, the outside unit is not blowing out any air either.
So I consulted with some other people and they are saying that since the thermostat is on cooling, the inside vents are blowing out room temperature air, the outside unit is not blowing out any air, and the circuit breaker was not tripped, they are saying that likely the capacitor is lacking a hard start kit. Since apparently changing the filter requires opening the slotted door which causes the shut off switch to be triggered and as a result the capacitor is having a hard time starting back up without a hard start kit. If anyone agrees or disagrees please let me know, I would really appreciate it. Thanks again for all your responses!
Get help from others!
Recent Answers
Recent Questions
© 2024 TransWikia.com. All rights reserved. Sites we Love: PCI Database, UKBizDB, Menu Kuliner, Sharing RPP