Portable AC leaking water....how to locate problem?

Home Improvement Asked by PacNW GS on December 20, 2020

Have an older portable AC — maybe 10 yrs old. Has been sitting in the garage unused for a couple of years. Gave it to my son to use and after a couple hours of running he reported there was a large puddle of water under it but the collection bin for the water (that needs to be manually emptied and sounds an alarm when it needs emptying ) was bone dry.

I tried 2 tests. First one i ran in the garage for a couple of hours. No leak…but also no water in the collection container. When preparing to bring it inside for test 2, I tipped it and water ran out, confirming that water was going somewhere….just not to the collection bin. I brought it inside and put a pan under the unit to catch any leaking water and ran it for a couple of hours. When i checked I found a puddle under the unit, no water in the tray I put under it, and the unit’s collection bucket was bone dry. When i was taking the unit back out to the garage and tipped it to get it down some stairs, the collected water came out.

Any idea how i can locate the leak? Do these things operate if I pull the back off and try to run it for a couple hours? It’s as if there is a hose inside the unit that is supposed to direct the condensate to the collection container but it has dislodged. Is that a possibility? thanks.

More info + pics:
Inside port AC

Port AC plug

See info on top pic. It makes sense if the secondary drain hose has a plug with a small hole in it, water will come out. I tested this.But what is puzzling is this thing has never been opened up. This is all original equipment. And it has never leaked before. The other odd thing is when i poured water into the condensate tray, it drained to the secondary hose first. I covered the hole in the secondary hose plug, and water eventually started flowing, as expected, into the condensate container. I figure the secondary hose just filled up, backed into the condensate reservoir, and found the drain hole into the condensate container.

So do I just plug the hole in the secondary hose’s plug? At least that seems like a place to start I suppose.

It is just so odd as there are no issues or rotting hoses, yet this leaking has never occurred before. And why is there a hole in the plug on the secondary container if it isn’t supposed to be there?

thanks.

One Answer

Pull off the back. It serves as a grilled vent so critters don't crawl in there. The unit will work fine. Look for a pan right under the cooling coils and then look for some hole in the pan that would allow it to drain into the collection container. There could be a hose that disintegrated or maybe the hole just got plugged up. Don't forget, the unit has to be level for it to drain properly.

Answered by JACK on December 20, 2020