Home Improvement Asked by Randy M on January 15, 2021
Hope you can take a look at the drawing and let me know if its ok to hook up the waste like this. The plan is to remove a section of gal at both locations in red and install a pvc sanitary tee and attach with 1-1/2″ Fernco Proflex couplings. The existing sink drain that will be removed is @ 14″ center. The 2 new drains will be @ 22″ center to get up inside the vanity. Hope this makes sense.
Thanks
You show a trap for the laundry, so you need a trap for both sinks and the shower, if you don't fit them then you could / will end up with smells coming in...
Answered by Solar Mike on January 15, 2021
It may not meet “code” due to the number of fixtures with just an 1-1/2” vent, but I think it will work fine. Also, “code” may require the vent to be 3” at least 18” before it exits the roof but I don’t think it’s necessary. The only worry with that is if you live in an extremely cold area. Good luck!
Answered by Eric Anderson on January 15, 2021