Home Improvement Asked on August 24, 2021
I have a stone fireplace in a cabin that I’d like to mount a television screen on. While I’d love to pay someone a reasonable fee to do so, the cabin is in a location where contractors are few and far between, and those I have spoken with are booking work six months out. I’d prefer to not wait that long.
I apologize for asking so many questions, but I’m trying to approach this job with as much preparation as possible. As my questions surround different parts of the job, I’ve grouped them and marked them as “Question Section #” along with the context below.
I’ve purchased an OmniMount OS120FM to use for mounting, and the TV is a Samsung 50”.
Here’s the fireplace:
It is an old wood burning fireplace which has been converted to gas with a vented gas log insert from Empire Comfort Systems (model DV33IN33L). There is an existing electrical outlet here which powers the gas logs on the back right hand side.
I realize that gas logs aren’t ideal to mount a TV above because of heat, so I’m willing to add a mantle if necessary. However, I did test the logs for three hours in May (outdoor temperatures around 51F, indoor around 68F), with the blower going full blast, and the max temperature I saw was 80F (ignore the outside temps at the top…they’re sourced from an outdoor sensor). The below thermometer is resting on the top of the gas log casing.
The Samsung manual states the operating temperatures for the TV is 50F – 104F. As it’s unusual for us to run the fireplace with the blowers going for that long (and if we were to do so, we’d only be doing it in the cold winter), I wonder if the temperature is going to be a concern. I would really appreciate your opinions here.
Question Section #1
Regarding the mounting itself, I’m hoping to line up the holes of the mount at a position where I only have to drill through the grout, but it’s possible I will have to drill through the rock itself. Since this was a fire burning fireplace before it was gas, I believe there will be brick behind the rock/grout.
If I understand what I’ve researched so far, I should be able to drill through this by purchasing a hammer drill with a special bit. After drilling, I should be able to mount it securely using mollies (https://en.wikipedia.org/wiki/Molly_(fastener)).
Question Section #2
Assuming the above is accurate:
Finally, I need to get power to the TV. As I mentioned previously there is an existing outlet behind the gas logs, and as I use a Fire TV stick (so no need for coax), I was thinking of drilling a hole directly into the flue and running an extension cord down it to the outlet. The only other thing running through the chimney now is ventilation piping. Here’s the outlet:
And here is the piping:
If this is a feasible approach:
Question Section #3
The other option I could see is removing grout between certain stones, running the wiring, and then re-grouting, but I’m worried that the grout won’t match…the existing grout is around 35 years old at my best estimate.
Finally, any other tips you can offer would be welcomed with extreme gratitude. I’m a fairly handy guy, but this is my first job involving this mix of components (drilling/mounting in stone, heat, etc), so I’m trying to be as careful as possible. If any of the above is the complete wrong approach, you’ll save me a lot of time and heartache by pointing me in the right direction.
Thanks so much!