TransWikia.com

Is the purple wire on AC blower motor common wire?

Home Improvement Asked on August 17, 2020

I’m replacing my AC blower motor. The old one had Red,Blue, Black wires for speeds, white Common, and brown & brown/white wires to the capacitor. (Yellow, purple wires for rotation).

The new motor has one rotation direction.
It has brown and purple wires going to the capacitor. Black, blue red for speeds. Where is the common wire?

According to the photo I’ve attached, am I supposed to connect a second wire to the capacitor terminal with purple wire, and connect the other end of this second wire to the control board connection where the white wire previously was?

Like this?

enter image description here

One Answer

Yes, your diagram is correct.

Your new motor appears to not be reversible so hopefully it spins in the correct direction.

Colours on equipment wiring generally do not mean anything aside from what is printed on the diagram; there are no consistent standards or requirements.

Answered by SomeoneSomewhereSupportsMonica on August 17, 2020

Add your own answers!

Ask a Question

Get help from others!