Fix issue with 2 independent lights on single source

Home Improvement Asked by rettug on March 21, 2021

I inherited an electrical conundrum. In particular, two hallway lights on the main floor and upstairs, sharing a circuit and each independently controlled by two switches, both on the main floor.

The main floor connections were a mess. No box; other than BX at the ceiling everything (cabling, switches) was surfaced mounted. The legs to the two switches were particularly unpleasant: flat nailed-in weathered 18/2 LVT cable running across walls and ceilings, not to mention some dead wires etc. Just a maze, so I decided to rip it all away and start over.

I knew what I wanted, and perhaps what the previous owner had tried to wire. Two hallway lights with independent 3-way switches. I planned to use wireless relays at the fixtures.

Upstairs was a snap even for an amateur like me. The short was just due to some fraying on both the hot and neutral. Cleaned up the 14/2 in the ceiling (shorted due to frayed wires), attached them to a wireless receiver I squeezed into the electrical box, connected it the fixture and put a pair of switches/transmitters upstairs and downstairs. Worked fine.

Next, I ripped out the LVT and switches. Should have paid more attention, because of course when I disconnected the switch for the upstairs light I opened that circuit.

I had envisioned the existing wiring to look like (switches & connections to fixtures omitted)

enter image description here

But of course that would not have made it possible for the main floor switch to control the upstairs light. Belated Duh!

At this point, the wiring to the old switches is irrelevant since they’re being replaced with relays at the fixtures. But I’m having trouble figuring out what the real (hidden) wiring is, and more practically how to energize the upstairs pair with the existing cables if possible.

One Answer

Oh my, I understand your frustration. I've recently moved from an 1856 + 1880 post and beam "building" house. I have not found any nobb and tube, but plenty of tar-paper covered 2 wire, and a ton of BX, all probably 14 & 16 g. There are new pulls of 14-2-G to junction boxes with the old wires, back to two 100A breaker boxes, installed in the 70's. Everything I've done is 14-2-G, 12-2-G or 14-3-G clear back to the breakers. The breaker boxes were "upstairs/downstairs" but I couldn't keep that. I feel your pain. You will probably need to (add to your tool box) get a circut identifyer for AC. IDK what they cost, but know I saw one the last time I was at Lowe's. I did find junction boxes burried below floor level from a remodel in the 1940's. They hacked a lot of things that time. This building had between 2 & 6 remodles per room. Yes, it was a blast! Getting the AC tracer will help you "find your way". I bought a Cat 3/4/5/6 set for pulling & finding network cable. That is the best way I can think of, if cutting a LOT of holes is not your plan. Good Luck. JLH

Answered by Joel Huebner on March 21, 2021