Home Improvement Asked by Illidanek on June 8, 2021
I have bought a new motion sensor for my corridor LEDs. The lights turn on fine with it, however, when the sensor is set to OFF, the lights blink indefinitely (a few times per second) and never actually turn off.
It turns out the sensor has a minimum watt requirement of 40W, and I’m quite certain the LEDs use less than that, so could that be the cause of the issue?
If so, how can I easily raise the wattage of the circuit?
And if that’s not it, then what could be causing this?
Thanks in advance!
Yes, that could be the cause depending on the electronics.
If you want to waste power? The better solution is to use another sensor.
The blinking, however, might also be caused by an induced current within the wiring. I had the case where I had a ceiling LED light would blink randomly when turned off, another one was always slightly on even when the switch was off. This was caused by long adjacent wires within the wall.
The LED were requiring so little power to turn on, that the coupling of the cables within the walls was enough to actually trigger the lamp to turn on. This problem probably does not happens with better quality lamps.
As suggested, try with a higher power lamp, and try with another LED lamp and observe if the behavior is similar.
Answered by Damien on June 8, 2021
This is common with sensors that are not listed for use with LED’s The sensor is drawing a tiny amount of power to power the electronics, this s just enough to cause a glow and sometimes flashing. You have 2 options use higher wattage lamps like you have tried to prove the sensor was working OR find an LED compatible sensor. I use motion sensors that work with LED’s you will find many of the led type need a neutral so they power the electronics with out drawing current through the lamps this is causing the flashing.
Answered by Ed Beal on June 8, 2021