An accepted method of leak testing a test piece is by using a differential measurement between it and a reference such as in the schematic here – why might one bother doing this as opposed to just comparing your test piece alone to a predefined or recorded leak rate, or curve?
Pressures change in a vessel based on ambient conditions. The reference volume removes that source of error.